GAI-Tronics ACC2500 Audio Control Center User Manual

Page 30

background image

Installation

ACC2500 Audio Control Center

09/08 26

Main Diagnostics Selection

To enter the main programming mode:

1. Remove power from the desk set.

2. Reapply power and wait for the

PB1

through

PB4

LED

S

to illuminate. (The display will indicate

“checking parameters - please wait.”) Press either

PB1,

PB2,

PB3,

or

PB4

to enter diagnostics.

3. The display will then indicate that the Main Diagnostics mode has been entered, and buttons PB1-PB4

can now be pressed. PB1 through PB4 are used to select different parameter changes from the default
settings.

PB1 – Line Output Adjust

An ac voltmeter or Sinadder meter should be connected across the line to achieve the proper level setting.
Ensure that the line is terminated with a 600-ohm load.

After entering the Main Diagnostic selection mode, press the

PB1

button. The display will indicate the

current setting, which is set at the factory at -10 dBm. The range for this setting is variable from off to
+12 dBm. See the Line Output Adjustment table for approximate settings. The desk set buttons are used
as follows in the Line Output Adjust mode:

Button

Line Output Level Adjustment Mode Function:

VOLUME

Up

Increases the output level, verifying the proper level with the meter connected
to the line.

CTL

+

VOLUME

Up

Increases the output level by 10.

VOLUME

Down

Decreases the output level, verifying the proper level with the meter connected
to the line.

CTL

+

VOLUME

Down

Decreases the output level by 10.

TRANSMIT

Saves the current setting and exits back to the main selection mode.

DEACT

Restores the previously programmed setting.

TIME

Exits the line output adjustment mode without saving the selection, but
maintains the current setting until the power to the unit is cycled. This is
useful for experimenting with different settings.