Installation

ACC2500 Audio Control Center

09/08 22

Table 1. Backup Data Terminations using XRC0001A

Signal

Relay Board J701

Primary RXD

23

Primary TXD

20

Backup RXD

21

Backup TXD

18

Primary GND

24

Backup GND

24

12612 pin 2

19

12612 pin 7

22

12612 pin 8

24

Mechanical Receipt Inspection

The desk sets are shipped in a cardboard container with inserts. Thoroughly inspect it as soon as possible
after delivery. In-transit damage should be immediately reported to the transportation company.

Mounting

The desk sets can be placed on a desk or mounted vertically on a wall. To wall mount the desk set, remove
the four bottom screws from the base and then rotate the base 180

°. Reinstall the four screws to the base

and rotate the handset hook located on the front of the unit.
N

OTE

: Certain configurations restrict wall mounting.

FCC Interference Warnings

The FCC requires that manuals pertaining to Class A and Class B computing devices contain warnings
about possible interference with local and residential radio and TV reception. Please read these warnings
and all safety information in the Foreword section of this manual.

Electrostatic Discharge (ESD) Protection

The ACC2500 have ESD protection circuitry that provides a high degree of protection against ESD, and
power and telephone line surges. The circuitry shunts the transient currents to earth ground through the
ground terminal. One of the two screws located on the back of the desk set can be used as an earth ground
terminal. See the rear view of the desk set for the ground screw terminal locations.

The ground terminal must be connected to a high quality earth ground point to obtain maximum protection.
Ideally, the ground point should originate at a 1/2-inch copper rod driven at least six feet into the soil with a
No. 16 AWG (or larger) copper wire run to the ground terminal taking the shortest path possible. Where
this is not possible, ground to a nearby water pipe or best available ground.