FSR ML-800 User Manual
Page 31
ML - 800
31
Membrane Wallplate Dip Switch Settings
The ML-800 allows for up to 16 wallplates: 2 per room up to 8 rooms. The wallplates must be
individually addressed. The addresses are set by setting the dip switches on the back of the wallplate.
The address is a binary code representing the room number minus one, given on switches 1 through 4
with a closure representing a 1.
.
Note: 0= switch open
1= switch closed
Switch 5 is used for rooms with two wallplates. In a two wallplate room, one and only one of the
wallplates (it does not matter which one) should have switch five closed.
Switches 6 through 8 are used for factory self tests and should be open for normal use.
1-5 ADDRESS
6-8 FACTORY USE ONLY
Picture of rear of wallplate
SWITCH
1 2 3 4
ROOM 1
0 0 0 0
ROOM 2
1 0 0 0
ROOM 3
0 1 0 0
ROOM 4
1 1 0 0
ROOM 5
0 0 1 0
ROOM 6
1 0 1 0
ROOM 7
0 1 1 0
ROOM 8
1 1 1 0
SWITCH POSITIONS