beautypg.com

FSR ML-800 User Manual

Page 29

background image

ML - 800

29

Dip switch 5 and 6

- Wallplate Interlock Mode.

If Switch 5 is closed, the wallplate keyswitch has no effect on the operation of the wallplate. The local
input and music sections of the wallplate are always active. In this position Switch 6 is not used.
If Switch 5 is open and Switch 6 is open, the ‘partial interlock’ mode is selected. This is the default
mode for the ML-116. In this mode, the keyswitch interlocks only the microphone section of the
wallplate.
If Switch 5 is open and Switch 6 is closed, the ‘full interlock’ mode is selected. In this mode, the
wallplate cannot be operated without the keyswitch.

Dip switch 7

- Reserved

Dip switch 8

- System Clear When system power is removed the ML-800 has the capability to

save the state of the system including the combining status of all the rooms and the state of each room’s
local input and music selectors and volume. If open, the System saves its states, if closed it initializes to
a “clear” state. System is shipped with this switch closed.

Dip switches 9 to 12

are used to address multiple ML-800’s. The coding is as follows:

12 11 10 9

ML-800 12 11 10 9

ML-800

O O O O

-

1

C O O O -

9

O O O C

-

2

C O O C -

10

O O C O

-

3

C O C O -

11

O O C C

-

4

C O C C -

12

O C O O

-

5

C C O O -

13

O C O C

-

6

C C O C -

14

O C C O

-

7

C C C O -

15

O C C C

-

8

C C C C -

16

Note: C=dip switch is closed, O= dip switch is open

These switches would only be used with a Facility Managers Panel and multiple ML-800 systems.

Dip Switch 13

- Reserved

Dip Switch 14

- Reserved

Dip Switch 15

- Reserved

Dip Switch 16

- Room audio input level. Unity gain switch open, +10dB gain switch closed