beautypg.com

Fronius IG 15 User Manual

Page 82

background image

74

Input data

IG 40

IG 60

IG 60 HV

Recommended PV power

3500-5500 Wp

4600-6700 Wp

4600-6700 Wp

MPP-voltage range

150 - 400 V

Max. input voltage
(at 1000 W/m² / - 10°C in no-load)

500 V

500 V

530 V

Max. input current

29,4 A

35,84 A

35,84 A

Output data

IG 40

IG 60

IG 60 HV

Nominal output power (P

nom

)

3,5 kW

4,6 kW

4,6 kW

Max. output power

4,1 kW

5 kW

5 kW

Nominal mains voltage

230 V, +10 / -15 % *

Nominal output current

15,22 A

20 A

20 A

Nominal frequency

50 +/-0,2 Hz *

Total harmonic distortion

< 3%

Power factor

1

General data

IG 40

IG 60

IG 60 HV

Maximum efficiency

94,3 %

94,3 %

94,3 %

Euro-efficiency

93,5 %

93,5 %

93,5 %

Consumption during night

0,15 W *

Consumption during operation

12 W

Cooling

controlled forced ventilation

Protection type (indoor/outdoor housing)

IP 21 / IP 45

Size l x w x h

610 x 344 x 220 mm / 733 x 435 x 225 mm

Weight

16 kg / max. 22 kg

Admissible ambient temperature
(at 95% rel. humidity)

-20 ... 50 °C **

Protection devices

IG 40

IG 60

IG 60 HV

DC-isolation monitoring

Warning / Shut-off

***)

when R

ISO

< 500 kilohms

DC-excess voltage protection

integrated

DC reverse polarity protection

integrated

Reaction at DC-overload

shift of operating point

*)

Values given are standard. Your FRONIUS IG unit has been specifically adjusted in
accordance with the regulations of your country.

**)

The AC-output reduces (power-derating) when the ambient temperature is increased,
from approx. 35 °C (dependent on the solar module voltage).

***)

Depending on the country setup

Fronius IG 40 /
60 / 60 HV

This manual is related to the following products: