63

ENEN

- Equipping a FRONIUS IG with a datalogger card

(Illustration: FRONIUS IG 2)

- Equipping all FRONIUS IGs with a COM Card

The data recorder has two RS-232 interfaces for the connection with
personal computer and modem.

COM Card

(5)

OUT

IN

Data recorder

PC

(5)

(6)

(6)

(6)

COM Card

COM Card

(5) Blind plug
(6) Data cable

Sensor Box in

external Housing

IN

OUT

IN

OUT

PC

IN

OUT

ENS

ENS

ENS

RS-232

Note! Basically the order of sequence for placing the cards does
not matter.
Important however is:
-

One FRONIUS IG can have only one COM card

-

One network can contain only one data recorder.

More information on the various system upgrade possbilities you will find in
the respective service manuals or in the internet under www.fronius.com.

Example