beautypg.com

Fronius IG 15 User Manual

Page 56

background image

48

Important! Dowels and screws are
not included as there are too many
different types on the market to suit
different wall surfaces.

- fix wall mounting frame (1) with

suitable screws (2) and dowels
(3) on to a solid base.

- Open the connection area of the

FRONIUS IG unit (chapter „Ope-
ning the Housing“)

(4)

Caution! There is a danger of the machine toppling over. Hang
the FRONIUS IG unit into the wall mounting frame and secure it
with screw (4) in the connection area.

- install AC and DC cable as described in chapter „Connection“.
- close connection area and mount cover by means of tightening screw.

The housing is designed for a cable channel of up to 50 mm height which
can be located directly below the connection area, without
- cables visible below the FRONIUS IG unit
- impairing access to the connection area and the slot- in board area

Fixing the wall
mounting
frame for
indoor hou-
sing

(continued)

Fixing the wall
mounting
frame for
indoor hou-
sing

Hazard due to supply voltage and DC-voltage from the solar modu-
les. Only licensed electricity installers are authorized to open the
connection area.

(2x)

(1x)

(1)

(2) (3)

(2) (3)

(4)

IG 30: 130 mm

IG 60: 373 mm