48
Important! Dowels and screws are
not included as there are too many
different types on the market to suit
different wall surfaces.
- fix wall mounting frame (1) with
suitable screws (2) and dowels
(3) on to a solid base.
- Open the connection area of the
FRONIUS IG unit (chapter „Ope-
ning the Housing“)
(4)
Caution! There is a danger of the machine toppling over. Hang
the FRONIUS IG unit into the wall mounting frame and secure it
with screw (4) in the connection area.
- install AC and DC cable as described in chapter „Connection“.
- close connection area and mount cover by means of tightening screw.
The housing is designed for a cable channel of up to 50 mm height which
can be located directly below the connection area, without
- cables visible below the FRONIUS IG unit
- impairing access to the connection area and the slot- in board area
Fixing the wall
mounting
frame for
indoor hou-
sing
(continued)
Fixing the wall
mounting
frame for
indoor hou-
sing
Hazard due to supply voltage and DC-voltage from the solar modu-
les. Only licensed electricity installers are authorized to open the
connection area.
(2x)
(1x)
(1)
(2) (3)
(2) (3)
(4)
IG 30: 130 mm
IG 60: 373 mm