Example

Example: Recording and archiving inverter and sensor data by means of a
datalogger card and sensor box.

The cards communicate within the FRONIUS IG unit via its internal net-
work. External communication (LocalNet) is effected via the COM cards.
Each COM card has two RS-485 interfaces for entry and exit. Connection
is effected with RJ45 plugs.

The first FRONIUS IG unit with COM card can be located at a distance of
up to 1000 m from the last FRONIUS IG unit with COM card.

LocalNet automatically identifies different system upgrades (data recor-
der, sensor card, ...)

To differentiate between several identical system upgradings, the respec-
tive units must have an individual number.

To define each FRONIUS IG clearly in the LocalNet, an individual number
must also be allocated to each FRONIUS IG.

For the respective procedure, please consult the chapter „Setup Menu“ in
your operating instructions.

Configuration

Insert slot-in
boards, FRO-
NIUS IG (for
external
mounting)

- Release four screws (1)
- Remove cover (2)
- Release fastening screw (4) and

remove cover the relevant slot
(se illustration in the section
„Insert slot-in boards FRONIUS
IG (for indoor housing)“.

Note! When dealing with
slot-in boards, please obser-
ve general ESD regulations.

- Insert board (3) in any of the slots
- Attach the board (3) with faste-

ning screw (4)

(2)

(1)

(1)

Note! Please see the versions and notes for the ENS card (in the
chapter „Insert slot-in card (for indoor housing)“.