66
Service codes of service class 1 appear mostly only temporarily, their
cause lies in the public mains network.
The first reaction of your FRONIUS IG unit is to disconnect from the
mains. Subsequently the mains network will be checked for the duration
of the observation period stipulated. If after the end of this period no
further defect is identified, your FRONIUS IG unit resumes operating and
feeding power into the mains network.
The following schedule lists a number of service codes with their respecti-
ve designation, description, and repair measures.
Class 1
FRONIUS IG resumes fee-
ding power into the mains
network as soon as the
mains network conditions
have returned to the per-
missible range following
detailed checking procedu-
res.
108
Islanding detected
Contact your installation
specialist if the service
code fails to disappear.
As soon as the mains volta-
ge, after detailed check pro-
cedure has returned to ad-
missible range, FRONIUS
IG resumes feeding power
into the mains network
101
Mains voltage not wi-
thin admissible range
Check mains voltage
If the service code does
not disappear you should
contact your installation
specialist
As soon as mains frequen-
cy after detailed check pro-
cedure has returned to ad-
missible range, FRONIUS
IG resumes feeding power
into the mains network
104
Mains frequency not wi-
thin admissible range
Check mains frequency
If the service code does
not disappear you should
contact your installation
specialist
As soon as the mains net-
work conditions after detai-
led check procedure have
returned to admissible ran-
ge, FRONIUS IG resumes
feeding power into the mains
network
107
AC mains network not
available
Check mains connec-
tions and fuses
If the service code does
not disappear you should
contact your installation
specialist
Code
Designation
Description
Repair