beautypg.com

Formax FD 2092 User Manual

Page 14

background image

3. Turn the speed control to ½ or full speed. Place

your thumb on the back of the stack to keep paper

from feeding. Press the green button, the sucker

wheel will start to turn. Reduce the pressure of your

thumb to feed only 3 to 4 sheets. Press your thumb

down to stop the feeding again. Press the red button

to stop the sucker from turning. If the paper did not

feed, adjust the position of the vacuum advance,

bleeder valve, or sheet separator.

4. Check the accuracy of the 3 or 4 sheets fed. It

may be necessary to adjust the fold stop, or the

squareness of the fold stop, or the squareness of

the side guides. Try only one adjustment at a time

then repeat step 3

5. If the folds look good, the job may now be run.

The speed of the folder will affect the accuracy of the

folds. Folds set up at slow speed will be difficult at

high speed and will need to be fine tuned.

NOTE: All of the controls mentioned above contribute

to smooth and accurate folding. There are many

combinations possible depending on the condition of

the paper and environment.

Bleeder Valve (Vacuum Adjustment)

There is a bleeder valve on the vacuum pump,

(Fig 26), which allows for vacuum adjustment from

completely off to completely on. General settings for

the bleeder valve are half open for 20# stock, and

closed for 80# and heavier stock. If your machine

is feeding doubles, this can be opened slightly to

“relieve” some of the vacuum and stop the double

feeding.

Separator Guide Lock

Set Screw

Air Blast

Openings

12

Fig 25

Fig 26

This manual is related to the following products: