MC6802
• MC6808 • MC6802NS
Bus Timing Characteristics
Ident.
Number
Characteristics Symbol
MC6802NS
MC6802
MC6808
MC68A02
MC68A08
MC68B02
MC68B08
Unit
Min. Max. Min. Max. Min. Max.
1 Cycle
Time
t
cyc 1.0 10 0.667
10 0.5 10
µS
2
Pulse Width, E Low
PW
EL 450 5000 280 5000 210 5000 ns
3
Pulse Width, E High
PW
EH 450 9500 280 9700 220 9700 ns
4
Clock Rise and Fall Time
t
r,
t
f --- 25 --- 25 --- 20 ns
9
Address Hold Time
t
AH 20 --- 20 --- 20 --- ns
12
Non-Muxed Address Valid
Time to E (see note 5)
t
AV1
t
AV2
160
---
---
270
100
---
---
---
50
---
---
---
ns
ns
17
Read Data Setup Time
t
DSR 100 --- 70 --- 60 --- ns
18
Read Data Hold Time
t
DHR 10 --- 10 --- 10 --- ns
19
Write Data Delay Time
t
DDW --- 225 --- 170 --- 160 ns
21
Write Data Hold Time
t
DHW 30 --- 20 --- 20 --- ns
29
Usable Access Time (See
Note 4)
t
ACC 605 --- 310 --- 235 --- ns
Figure 3-4. Read/Write Timing Diagram
Notes:
1. Voltage levels shown are V
L
< 0.4 V, V
H
> 2.4 V, unless otherwise specified.
2. Measurement points shown are 0.8 V and 2.0 V, unless otherwise noted.
3. All electricals shown for the MC6802 apply to the MC6802NS and MC6808, unless otherwise noted.
4. Usable access time is computed by: 12 + 3 + 4 – 17.