Applicable Emissions standards
EN61000-6-4:2007+A1:2011
Industrial Environments - Class A - Test Limits & Levels
Radiated emissions
EN55011:2009+A1:2010 (CISPR11)
330 MHz to 230 MHz
230 MHz to 1 GHz
40 dB (μV/m)
47 dB (μV/m)
FCC Part 15, (CFR47 Part 15.109
30 MHz to 88 MHz
88 MHz to 216 MHz
216 MHz to 960 MHz
> 960 MHz
90 dB (μV/m)
150 dB (μV/m)
210 dB (μV/m)
300 dB (μV/m)
Conducted emissions
EN55011:2009+A1:2010 (CISPR11)
150 kHz to 500 kHz
500 kHz to 30 MHz
79 dB (μV) (quasi-pk), 66 dB (μV) (avg)
73 dB (μV) (quasi-pk), 60 dB (μV) (avg)
FCC Part 15, (CFR47 Part 15.107)
Applicable immunity standards
EN61000-6-2:2005 (Perf. Criteron)
Industrial Environments - Test Limits & Levels
ESD
IEC61000-4-2 (B)
Air: AC, DC, Signal
Contact: AC, DC, Signal
±2 kV, ±4 kV, ±8 kV
±1 kV, ±2 kV, ±4 kV
Radiated RF immunity
IEC61000-4-3 (A)
Enclosure @ 80 MHz to 1 GHz
10 Vrms/m @ 80% AM, 1 kHz
Enclosure @ 1 GHz to 2.7 GHz
3 Vrms/m @ 80% AM, 1 kHz
Fast transients/burst
IEC61000-4-4 (B)
AC, Signal
±2 kV, ±1 kV
Voltage surges
IEC61000-4-5 (B)
Common: AC, Signal
Differential: AC, Signal
±2 kV, ±l kV
±l kV, ±l kV
Conducted RF immunity
IEC61000-4-6 (A)
AC @ 150 kHz to 80 MHz
10 Vrms @ 80% AM, 1 kHz
Magnetic field immunity
IEC61000-4-8 (A)
Three mounting axis
30A/m
Voltage dips and interrupts
IEC61000-4-11 (B)
3 dips, 10 sec apart
> 95% dip for 1 cycle @ 50/60 Hz
30% dip for 500 ms @ 50/60 Hz
60% dip for 200 ms @ 50/60 Hz
IEC61000-4-11 (C)
3 dips, 10 sec apart
> 95% interrupt for 5 sec @ 50/60 Hz
Table 7.1 – EMC – Electromagnetic Compatibility (EMC) and Electromagnetic Interference (EMI) standards to which this
actuator complies: