FAULT SYMPTOM
Motor protection triggered
⇓
⇓ Pump does not start
⇓
⇓ Flow inadequate
⇓
⇓ Pumping unit runs, but does not pump
⇓
⇓ Shut-off head current (amps) is higher than originally recorded but shut-off head is not diminished
⇓
⇓ Shut-off head is diminished but shut-off current (amps) is unchanged
⇓
⇓ Shut-off head is diminished and shut-off current (amps) is much higher
⇓
⇓ Duty capacity and head are low but running current (amps) and shut-off valves are normal
⇓
⇓ Pump starts bus trips circuit breaker
⇓
⇓ Pump does not start
⇓
⇓ PROBABLE CAUSES
POSSIBLE REMEDIES
z
Blockage in discharge or intake
Disassemble and clean discharge and
intake.
z
Valve in system is not fully open
Fully open valve
C. ELECTRICAL TROUBLES
z Motor
circuit
breaker
adjusted
too
low.
Readjust motor circuit breaker
according to rating plate or Chapter
12.2 "Data sheet".
z Current
consumption
of
motor
too
high
due
to
under voltage or wrong frequency.
Check system voltage and frequency.
Check if the information on the type
plate corresponds with the system
voltage and frequency.
z
Phase failure.
Check fuses.
Examine power cables for damage.
z Voltage
failure
due
to
blown
fuse(s).
Replace
fuse(s).
z Defective
power
cable.
Replace
power
cable.
z Incorrect
rotating
direction.
Change
rotating
direction.
z Rotating
speed
too
low
because
of
under
volt-
age or wrong frequency.
Check system voltage and frequency.
z Rotating
speed
too
low
because
motor
runs
with one phase.
Check fuses.
z Rotating
speed
too
low
due
to
bearing
dam-
age.
Remove pumping unit and repair.
z z Drop
in
line
voltage
If
amperage
remains
within
110
%
of
the rated value: No remedy necessary.
If amerage does not remain within
110 % of the rate value: Check line
voltage
z
Insulation failure
Measure insulation resistance.
z Insulation failure
Measure insulation resistance.
Check voltage.
z Pumping unit is stuck
Try momentarily reversing rotation by
interchanging any two leads