Storage and shipping, 3 "storage and ship – Flowserve Byron Jackson Type M User Manual
Page 12

Byron Jackson Double Mechanical Seal Submersible Pumping Unit • 1042.293/9 • June
04
Page 12 of 68
2.3 Storage and shipping
For the removal of the pump from the well see
Chapter 4.5 "Uninstallation", Page 45, if necessary.
Requirements for the storage area
•
Safe
•
Clean
•
Away from extended periods of direct sunlight
•
Well ventilated
•
Dry
Air humidity: ................................40 % to 60 %
•
Cool
Air temperature for motors
originally filled by Flowserve: ...+50 °C to -5 °C
CAUTION Always store motor and pump bowl
assembly separately.
Prepare motor for storage or shipping after re-
moving the motor from the well
1.
Arrange the motor horizontally.
2. If pump and coupling are to be stored or
shipped separately: Install coupling compo-
nents on motor shaft.
3. Install power terminal shipping cap (112),
power terminal gasket (744-6), and motor
shipping caps (112-1).
4. If the motor is to be stored in a vertical posi-
tion, proceed as follows:
a.
Remove the adapter bracket (808).
b.
Drill a vent hole in the motor shipping cap
(112-1).
If the motor is returned to factory at a
later time, seal the vent hole by a pipe
plug.
5. If the motor is to be returned to the factory,
proceed as follows:
a.
Remove motor half-coupling (529) or mo-
tor one-piece coupling (531).
b. Lubricate shaft with some form of pene-
trating oil.
c.
Place coupling and components in motor
shipping cap (112-1) with its power ter-
minal gasket (744-6) and bolt cap se-
curely in place.
d. Elevate motor over a sump or drum to
drain oil and water from motor.
e. Remove lower casing drain plug (806)
from bottom of motor, then remove vent
plugs (806-4 and 806-5) at top of motor
and allow motor to fully drain.
f.
Replace drain and vent plugs.
Prepare pump bowl assembly for storage or
shipping
NOTE Not all components or sub-
assemblies of a pumping unit are
necessarily supplied by Flowserve
or part of this delivery.
These user instructions apply only
to the components or sub-
assemblies supplied by Flowserve
in this delivery, see Chapter 12.1
"Scope of delivery".
NOTE
The following description refers to
pumps without auxiliary carriers.
Should the pump be delivered on an
auxiliary carrier, refer to the pump
manual for storage and shipping
instructions.
1. Install blocks in the strainer to restrain the
pump shaft.
This prevents shaft end float and possible in-
ternal damage during handling.
2. Make sure the bowl assembly is thoroughly
dry.
3.
Install suitable covers to seal off all openings.