Fasten the power cable to the cable guard – Flowserve Byron Jackson Type M User Manual
Page 39

Byron Jackson Double Mechanical Seal Submersible Pumping Unit • 1042.293/9 • June
04
Page 39 of 68
4.4.12 Fasten the power cable to the cable
guard
Figure 28 Outer guard and band in place - example
1. Inspect cable guards, particularly their inner
surfaces, for sharp edges that could damage
the cable jacket or insulation.
2. Support the cable alongside the pump bowl
assembly with the cable installation wheel
without stretching or straining the terminal
box.
CAUTION The attachment of the power cable
to the cable guard depends on the
type of the pump bowl assembly.
3.
Slightly lift the pumping unit.
4. Remove
the
U-plate.
Use to 2 persons to remove the
U-plate.
Handle the U-plate carefully.
Danger of injury by dropping the
U-plate onto parts of the body.
5.
Install a clamp to hold the pumping unit.
The pumping unit is now ready for the attachment
of riser pipe and lowering into the well.
- CESM-4 (28 pages)
- CESM-1 (32 pages)
- ATEX N (20 pages)
- CESM-2 (32 pages)
- PVML (29 pages)
- WDX (46 pages)
- WX Worthington (51 pages)
- WX Worthington (52 pages)
- WMA2 (35 pages)
- Type RX (56 pages)
- LCH (40 pages)
- NM (48 pages)
- MJ Slurry (42 pages)
- Mark 3 (48 pages)
- MF (50 pages)
- MN (49 pages)
- CPXVC (32 pages)
- M Slurry (60 pages)
- PolyChem GRP (52 pages)
- CPXV fitted with FRBH hydraulics (44 pages)
- Durco Mark 3 ISO Frame Mounted (52 pages)
- MP1 Sier-Bath (48 pages)
- Twin Screw Rotary (56 pages)
- LNNC (56 pages)
- IDP CPXRV (48 pages)
- HWX Worthington (40 pages)
- U-MAG INNOMAG (40 pages)
- N-Series Worthington (20 pages)
- TB-MAG INNOMAG (44 pages)
- HDX IDP (64 pages)
- QLQC Vertical Worthington (61 pages)
- LPNV Worthington (48 pages)
- Mark 3 ISO Durco (32 pages)
- FP (40 pages)
- FP (40 pages)
- FM (36 pages)
- MEN-TI (36 pages)
- MEN (36 pages)
- MENBLOC 60Hz (36 pages)
- ME (36 pages)
- PVXM (31 pages)
- VTP (76 pages)
- PLEUGER (40 pages)
- APKD (55 pages)
- WJE IDP (28 pages)