Flowserve Byron Jackson Type M User Manual
Page 20

Byron Jackson Double Mechanical Seal Submersible Pumping Unit • 1042.293/9 • June
04
Page 20 of 68
•
An adequate supply of approved thread com-
pounds, as follows
-
For installation of the short section of col-
umn pipe, next to top case or top case
flange, use only Loctite
277 (Red) &
Primer T or equal.
-
For remaining column pipe threads, use a
pipe thread compound that is capable of
lubricating and sealing.
Column
Size
Weight per foot in kg (pounds)
Empty
Full
2-1/2
2.6 (5.8) 3.6 (7.9)
3
3.4 (7.6) 4.9 (10.8)
4
4.9 (10.9) 7.4 (16.4)
5
6.7
(14.8)
10.7
(23.5)
6
8.7
(19.2)
14.4
(31.7)
8
11.3 (25.0) 21.4 (47.2)
10
14.5 (32.0) 30.2 (66.6)
12
20.4 (45.0) 42.6 (93.9)
Bowl Slumps
Size
Weight in kg (pounds)
1
st
Stage
Additional Stage
8MQ
36
(80)
7
(15)
10MQ
79 (175) 17 (37)
11MQ
132
(290)
32
(70)
12MQ
200
(440)
57
(125)
13MQ
284
(625)
79
(175)
15MQ
386 (850) 120 (265)
Cable
Volts Size
Weight
per
foot
in kg (pounds)
8
0.14
(0.30)
4
0.35
(0.77)
2
0.50
(1.10)
300MCM
2.00
(4.40)
600
500MCM
3.08
(6.80)
6
0.41
(0.90)
2
0.54
(1.20)
1/0
1.00
(2.20)
5000
4/0
1.54
(3.40)
Motors
Nominal motor
size
Horsepower Weight
in kg (pounds)
7-1/2
211
(465)
10
211
(465)
20
227
(500)
25
249
(550)
8"
30
249
(550)
40
431
(950)
50
431
(950)
60
458
(1
010)
75
458
(1
010)
100
490
(1
080)
10"
125
553
(1
220)
125
915
(2
018)
150
953
(2
100)
175
1 002
(2 210)
12"
200
1 027
(2 265)
125
1 170
(2 580)
150
1 288
(2 840)
200
1 424
(3 140)
250
1 485
(3 273)
14"
300
1 485
(3 273)
300
1 690
(3 725)
350
1 860
(4 100)
400
1 928
(4 250)
450
1 996
(4 400)
500
1 996
(4 400)
17"
600
2 087
(4 600)
600
1 950
(4 300)
800
2 359
(5 200)
1 000
2 767
(6 100)
1 200
3 221
(7 100)
21"
1 500
3 720
(8 200)
Table 3
Component weight chart for calculating
foundation, derrick and hoist loads