Ip screen – Drake EEG-QIP Enterprise Edge Guide with QAM and IP Input / CHIC Software User Manual
Page 13

13
937.746.4556 |
www.rldrake.com
IP Screen
The “Main > IP” screen is a “read and write” screen to assign IP parameters for the TS:
Destination IP: allows user to assign the IP address of the equipment to which the IP output is streamed to.
Encapsulation: from the two available options (RTP & UDP) must select the one that matches the protocol used
by the receiving equipment.
Destination Port: must enter the IP Port of the receiving equipment. The factory default value is 50000. The range
is 1 to 65535.
Source Port: must enter the IP Port of the equipment that the input IP source is streamed from. The factory default
value is 50000. The range is 1 to 65535.
NOTE: Port number is recommended to be from 49152 to 65535. Reason: Port 1-1023 and 1024-49151
are the Reserved Ports and the Registered Ports, respectively.
Time to Live: is an upper bound on the time that an IP packet can exist in an IP network. The value is set by
the sender of the packet, and reduced by every host on the route to packet’s final destination. If the Time to Live
reaches zero before the packet arrives at its final destination, then the packet is discarded. The purpose of this field
is to avoid an undeliverable packet from circulating on an IP network perpetually. The range is 1 to 255. Factory
default value is 128.
Stuffing: Null packets are inserted to ensure that the TS bitrate remains constant. Possible options are Enable and
Disable. It is advisable to Disable stuffing when only IP output is used to help reduce the traffic on the network.
1
2
3
4
5
6
1
2
3
4
5
6