beautypg.com

Tally assignment configuration web page – DNF Controls USP-S User Manual

Page 17

background image

Page 17 of 27

11. TALLY ASSIGNMENT Configuration Web Page

Use the Tally Assignment Table to assign a tally to a key. The Tally Assignment Table
contains one entry for each key. A key can tally OFF and ON, or up to 4 states (OFF,
ET1, ET2, ET3).

Key Number The USP-S24/48 keys are identified by their Column, Row position for easy

identification. Key number #11 is located in column #1, on row #1. Key number #16 is
located in column #1, on row #6. Key number #84 is located in column #8, on row #4.

Key Label Enter any 32 characters. This label is for convenience only and is used only on this

web page.

Tally Type Local- Tally local GPI, GPO, or key press

Remote- Tally status from Remote Device (GTP-32/DC20 Device Type)

Local

Follow Key- Tally is ON when key is pressed

Tally is OFF when key is released

Follow GPI- Tally is ON when GPI is ON

Tally is OFF when GPI is OFF

Follow GPO- Tally is ON when GPO is ON

Tally is OFF when GPO is OFF

Tally Source

Remote Follow GTP/DC- Assign one Event Label

Tally is ON when assigned Event Label is ON

Tally is OFF when assigned Event Label is OFF

Extended Follow GTP/DC- Assign up to 4 Event Labels

Tally is ON when any of the assigned Event Labels is ON

The associated Event Label’s color entry is used

Tally is OFF when all assigned Event Labels are OFF