Tally assignment configuration web page – DNF Controls USP-S User Manual
Page 17
Page 17 of 27
11. TALLY ASSIGNMENT Configuration Web Page
Use the Tally Assignment Table to assign a tally to a key. The Tally Assignment Table
contains one entry for each key. A key can tally OFF and ON, or up to 4 states (OFF,
ET1, ET2, ET3).
Key Number The USP-S24/48 keys are identified by their Column, Row position for easy
identification. Key number #11 is located in column #1, on row #1. Key number #16 is
located in column #1, on row #6. Key number #84 is located in column #8, on row #4.
Key Label Enter any 32 characters. This label is for convenience only and is used only on this
web page.
Tally Type Local- Tally local GPI, GPO, or key press
Remote- Tally status from Remote Device (GTP-32/DC20 Device Type)
Local
Follow Key- Tally is ON when key is pressed
Tally is OFF when key is released
Follow GPI- Tally is ON when GPI is ON
Tally is OFF when GPI is OFF
Follow GPO- Tally is ON when GPO is ON
Tally is OFF when GPO is OFF
Tally Source
Remote Follow GTP/DC- Assign one Event Label
Tally is ON when assigned Event Label is ON
Tally is OFF when assigned Event Label is OFF
Extended Follow GTP/DC- Assign up to 4 Event Labels
Tally is ON when any of the assigned Event Labels is ON
The associated Event Label’s color entry is used
Tally is OFF when all assigned Event Labels are OFF