DNF Controls AnyWhere Interface Switch User Manual
Page 12

Page 12 of 20
Step Number Identifies the 1 – 10 Steps displayed. Set the number of Steps and Actions by using the
Steps/ Actions Configuration at the top of the web page.
Device For each Action, select LOCAL or a specific Remote Device to affect
Control
Action
For Local Device:
Do Nothing
No action executed
Local GPO ON
Turn ON selected GPO
Local GPO OFF
Turn OFF selected GPO
Local GPO Toggle
Toggle the selected GPO. If ON, then turn it OFF. If OFF,
then turn it ON.
Goto Step #1
The switch goes back to its first step
Continue to Next Step
After executing the Actions for the current Step, execute
the Actions for the next Step.
Set Switch #1 to Step# Set Switch #1 to the indicated Step number
Set Switch #2 to Step# Set Switch #2 to the indicated Step number
Set Switch #3 to Step# Set Switch #3 to the indicated Step number
Set Switch #4 to Step# Set Switch #4 to the indicated Step number
Pause
Wait 0.25 seconds to 10 seconds before executing the next
Action
For Remote Device:
GTP/DC:
Key Press
Key Release
GPO Status
Transmit Key Press notification to GTP/DC
Transmit Key Release notification to GTP/DC
Transmit (USP) GPO status notification to GTP/DC
USP:
Key Press
Transmit Key Press notification to USP
EXT Tally:
Transmit Command
Transmit the user entered ASCII/ Hex command
Other:
Transmit Command
Transmit the user entered ASCII/ Hex command