6. SWITCH- Steps/ Actions Configuration Web Page
Each switch supports a sequence of 10 switch presses and 5 actions for each switch press. After
power up, the first switch press will cause the Step #1 actions to be executed. The second switch
press will cause the Step #2 actions to be executed. The third switch press will cause the Step #3
actions to be executed. After executing the Step 10 actions, the next switch press will cause the
Step #1 actions to be executed. All Actions are executed in the order displayed. An Action must
complete before the next Action will be executed.
This configuration pages sets the actual number of Steps that will be used and the number of actions
per step that will be used.
Steps Select 1 – 10. Every switch press will advance to the next step number per the MODE
selection.
Actions Select 1 – 5. Each switch press will execute the indicated number of user assigned actions.
Link Select None, Group A or Group B.
On each Group A switch’s switch press, all Group A switches will go to that switch’s Step
number.
On each Group B switch’s switch press, all Group B switches will go to that switch’s Step
number.
All grouped keys will be on the same Step number at all times.
Switches set to NONE will operate independently from all other switches.
Mode Execute Next Step: Execute the current switch Step number and then advance to the
next Step number. After executing the last Step number, go to the first Step number.
Execute
Previous Step:
Execute the current switch Step number and then go to the
previous Step number. After executing the first Step number, go to the last Step number.
Next Step
Execute:
Go to the next Step number and then execute its actions. If on the
last Step number, go to the first Step number.
Previous Step
Execute:
Go to the previous Step number and then execute its actions.
If on the first Step number, go to the last Step number.