beautypg.com

Chapter 7 save & exit, Security – DFI DT122-HR Manual User Manual

Page 50

background image

www.dfi .com

50

Chapter 7 BIOS Setup

Chapter 7

Save & Exit

Restore/Load Default
values for all the setup
options.

Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.

Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.

Save Changes and Reset
Discard Changes and Reset

Restore Defaults

Save as User Defaults
Restore User Defaults

Boot Override

Launch EFI Shell from fi le system device

Chipset

Advanced

Main

Boot

Security

Save & Exit



Select Screen



Select Item

Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous

Values

F3: Optimized

Defaults

F4: Save & Exit
ESC: Exit

Save Changes and Reset

To save the changes, select this field and then press . A dialog box will appear.

Select Yes to reset the system after saving all changes made.

Discard Changes and Reset

To discard the changes, select this field and then press . A dialog box will appear.

Select Yes to reset the system setup without saving any changes.

Restore Defaults

To restore and load the optimized default values, select this field and then press .

A dialog box will appear. Select Yes to restore the default values of all the setup options.

Save as User Defaults

To save changes done so far as user default, select this field and then press . A

dialog box will appear. Select Yes to save values as user default.

Restore User Defaults

To restore user default to all the setup options, select this field and then press . A

dialog box will appear. Select Yes to restore user default.

Security

Set Setup Administrator
Password.

Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.

Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.

Password Description

If ONLY the Administrator’s password is set,
then this only limits access to Setup and is only
asked for when entering Setup.
If ONLY the User’s password is set, then this
is a power on password and must be entered to
boot or enter Setup. In Setup the User will have
Administrator rights.
The password must be 3 to 20 characters long.

Administrator Password

User Password

Save & Exit

Chipset

Advanced

Main

Boot

Security



Select Screen



Select Item

Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous

Values

F3: Optimized

Defaults

F4: Save & Exit
ESC: Exit

Administrator Password

Sets the administrator password.

User Password