Datatek HP-UX 10.20 (32 bit kernel User Manual
Page 12

I P - C o m m K i t I n s t a l l a t i o n a n d A d m i n i s t r a t i o n G u i d e
f o r H P - U X – I s s u e 2 – R e l e a s e 1 . 0 . 2 2
10/13/11
Datatek Applications Inc.
12
CC0>
enter group
GROUP [up to 8 chars]: nodename
TYPE [local, trunk: +(local)]:
local
DIRECTION [originate, receive, 2way]:
2way
DEVICE OR HOST [up to 8 chars: +(standard)]:
PASSWORD [up to 8 chars, none: +(none)]:
ROUND ROBIN SERVICE [per_port, per_module, none: +(none)]:
GROUP [up to 8 chars]:
Next, enter an address. An address is bound to one or more groups. In this simple example,
there is one group, with one UTM in the group. We use the same name for the group and
address in this example, although it’s not required.
CC0>
enter address
LEVEL [network, area, exchange, local, speedcall: +(local)]:
TYPE [numeric, mnemonic, both: +(mnemonic)]:
MNEMONIC ADDRESS [up to 8 chars]: nodename
PAD SUPPORT [yes, no: +(no)]:
DIRECTORY ENTRY [up to 30 chars double quoted, none: +(none)]:
"appropriate description of host"
GROUP(S) [up to 4 groups separated by commas, none: +(none)]:
nodename
ORIGINATING GROUP NAME SECURITY PATTERN(S)
[comma-separated pattern list, same_as, none: +(none
)]: