INITIAL SERVICE STATE [in, out: +(out)]:
in
LEVEL [network, area, exchange, local, speedcall: +(local)]:
Next, enter the cpm. In reality, the cpm is a UTM, but the BNS controller can’t tell the difference.
In the dialog below, you must use values for mod_address and num_channels that are correct
for your configuration. Use the slot number where you installed the UTM for the mod_address.
By default, dkdaemon(1M) sets the number of channels per UTM to 64, so use this value for
num_channels. If you want to use more channels, you must modify the dkitcfg file. See section
3.6.2
CC0>
enter cpm
MODULE ADDRESS: mod_address
COMMENT [up to 60 chars double quoted, or none: +(none)]:
"appropriate comment"
HARDWARE TYPE [422, hs: +(hs)]:
NUMBER OF CHANNELS [3-512: +(32)]: num_channels
CALL SCREENING PROFILE ID [up to 8 chars, none: +(none)]:
CONNECT-TIME BILLING [on, off: +(off)]:
SINGLE OR MULTIPLE GROUPS [single, multiple: +(single)]:
GROUP [up to 8 chars]: nodename
ENDPOINT NUMBER OR RANGE [0000-9999, none: +(none)]:
MODULE ADDRESS: