beautypg.com

Figure 32: can temp sensor wiring – Daktronics AF-3165-34-RGB User Manual

Page 33

background image

Electrical Installation

29

Using the Quick Connect and less then the 10 foot cable

1. Run ¾" conduit from the sensor location to the Quick connect Temp Sensor input at the back

of the first display. The cable must be routed through ¾" metal conduit that should be earth-
grounded to protect the sensor and controller from lightning damage.

2. Disconnect the CAN temp sensor cable from the temperature sensor terminal block in the

CAN temp sensor housing. (0A-1241-4017)

3. Cut the cable to desired length and reattach to the temperature sensor terminal black in the

CAN temp sensor housing as follows:

Wire Color Terminal Block (TB1)

Red

+5V CAN

Green

CANH

White

CANL

Black

GND CAN

*Note: Do not terminate shield at this point.

Figure 32: CAN Temp Sensor Wiring