beautypg.com

Venus 1500 radio client, Figure 29: venus 1500 radio – Daktronics AF-3165-34-RGB User Manual

Page 29

background image

Electrical Installation

25

Venus 1500 Radio Client

A display that is controlled using a radio requires a Server radio connected to the control computer,
and a Client radio at the display. The radios must be within line-of-site of each other. The diagram
below shows the connections through a Signal Converter. The Client radio must be located within 25
feet of the display, therefore 25 feet of cable is supplied with the Client radio. One end of the cable is
pre-terminated to TB1 inside the radio enclosure, and a Quick connect plug is terminated at the other
end of the cable. The cable can be cut and terminated directly to the Signal termination Panel in the
display. Refer to Drawing A-175387 and the Radio manual (ED13348) for the correct cable
terminations.

1. If using a quick connect cable, connect from the Client Radio to J33 on the back of the

display.

2. When connecting directly to the display, terminate the other end of the cable to the 6-position

terminal block (TB1) on the Signal Termination Panel, labeled “RS232 IN”


Client Radio to Signal Term Panel (A35)

Venus 1500

Radio Client

Field Cabling

Signal Term

Panel (TB1)

Pin 6 (TX-P)

Red 2

Pin 1 (RX-P)

Pin 5 (RX-P)

Black 2

Pin 2 (TX-P)

Pin 4 (GND)

Black 3

Pin 3 (GND)

Pin 7 (10V Unreg)

Black 1

Pin 6 (10V Unreg)

Pin 8 (10 V Unreg)

Red 1

Pin 5 (10V Unreg)

Shield

Pin 4 (Shield)

Figure 29: Venus 1500 Radio