beautypg.com

Rs-232, Figure 20: signal termination display rear view, Figure 21: rs232 quick connect – Daktronics AF-3165-34-RGB User Manual

Page 23

background image

Electrical Installation

19


RS-232

A display that is controlled using RS-232 requires the use of a J-box within 25 feet of the display.
From the J-box to the display, the signal may be connected using a quick connect cable or directly
wired to the signal termination panel inside the display. The cable from the J-box to the display must
be routed though conduit. Do not run signal and display power through the same conduit.

1. If using a quick connect cable, connect from the J-box to J33 on the back of the display.
2. When connecting directly to the display, terminate one end at the J-box and the other end of

the wire to the 6-position terminal block in the display labeled “RS232 IN” (A35-TB1).
Drawing B-175387 shows the terminal block wiring.

The controlling laptop computer connects to the J-box through the serial cable (refer to Drawing A-
174341).

Figure 20: Signal Termination Display Rear View


Figure 21: RS232 Quick Connect