beautypg.com

Daktronics DF-12xx User Manual

Page 16

background image

2-4 Electrical

Installation

terminates at the driver enclosure. The DataMaster hand-held controller receives its
power from the display. The display layout is shown in

Figure 1

and Drawing A-

164988.


Note: The cable from the j-box to the display needs to be routed through conduit or

the display pole to protect it from weather and vandalism.

1. Mount the j-box near the display.
2.
Route a 4-conductor, 22 AWG, shielded cable through conduit from the j-box

to the driver enclosure in the host display. (Distance limit from the j-box to
the display is 50 ft.)

3. Connect the signal/power cable from the j-box to the driver enclosure as

shown in

Figure

2 and listed in the table. Refer to Drawings A-175342 and

A-184918 for additional information.

4. Using a DB9M to DB9F serial cable, plug the DataMaster controller into the

J-box, connected to the Host Display Driver Enclosure

J-Box to Driver Enclosure Input Jack

J-Box

Pin#

Cable

Color

Enclosure Terminal

Block

Pin 1

Red

12V DC Out (+) pin 7

Pin 5

Black

12 V DC Out (-) Pin 8

Pin 5

White

Signal IN (-) Pin 2

Pin 6

Green

Signal IN (+) Pin 1

Figure 1: Direct, Current Loop Layout