3.4 PID PROG

Press

for 3 seconds in the main screen to enter the “initial setting mode”. Press

several

times until the parameter

is displayed.

Display

Explanations

PV

SV

Status of the temperature controller

The control modes include: ON/OFF, MANUAL, PID and PID
PROG. Default = PID. Select “PID PROG” here.

DTB offers 8 patterns and 8 steps for each pattern, totaling 64
steps. Range of a pattern: OFF ~ 7. OFF = the function disabled.

Temperature SV for pattern 0 and step 0

Time SV for pattern 0 and step 0

Temperature SV for pattern 0 and step 1

Time SV for pattern 0 and step 1

… … …
… … …

Temperature SV for pattern 0 and step 7

Time SV for pattern 0 and step 7

Actual number of steps executed in pattern 0

Actual number of loops executed in pattern 0

Pattern linked after the execution of pattern 0 is completed.
OFF = end of linking patterns

Return to

Back to

top

Press

to return to the main screen.

Return to the main screen to switch to the functions below.