Base Modem Mode

3-44

VLoad User Guide

Figure 3-40 Select Base Modem Image / Codecast Select Base Modem Image dialog

Because Codecast utilizes multicast with no verification, the Codecast Select

Base Modem Image dialog displays the following IP multicast parameter

settings:

# Passes – the number of transmissions to each unit (default is 3).
Pause – the time, in seconds, between transmissions (default is 5 sec).
Time to Live – the maximum number of router hops/seconds to reach a

unit before the data packet expires (default is 10). This parameter prevents

possible looping of the packet transmission in the network.

Local Address – the address of the network interface card (NIC) on the

local host machine to be used for the multicast. If necessary, the specific

IP address can be entered; otherwise, the Any box should be checked. This

parameter is provided to accomodate host machines that have multiple

NICs.

These settings are editable; however, the default values are typically adequate

for most networks.
The default Base Modem Image To Run can be designated by clicking on the

desired Image radio button:

Image #1 – The base modem will run from the image in the target unit’s

slot with the label of Image #1.

Image #2 – The base modem will run from the image in the target unit’s

slot with the label of Image #2.

Note that the Unit Information window can be opened to view the firmware

version for each of the images.
Refer to the “Image Selection” section on page 3-15 for additional information.