6 select: monit (monitor), Monit:) alarms, Monit: alarms) unit (unit alarms) – Comtech EF Data CDM-550T User Manual
Page 66: Monit: alarms) receive (receive alarms)
CDM-550T Satellite Modem
Revision 3
Front Panel Operation
MN/CDM550T.IOM
6.2.6
SELECT: MONIT (Monitor)
Select ALARMS, RX-PARAMS, STORED EVENTS, STATS, or AUPC or using the [
←] [→]
arrow keys, then press ENTER.
If the user selects ALARMS, the following sub-menu is displayed:
MONITOR:ALARMS RX-PARAMS
STORED-EVENTS STATS AUPC
6.2.6.1
(MONIT:) ALARMS
Select UNIT, RECEIVE, or TRANSMIT using the [
←] [→] arrow keys, then press ENTER.
Depending on the choice selected, one of the following menus will be displayed:
LIVE ALARMS: UNIT
RECEIVE TRANSMIT
6.2.6.1.1
(MONIT: ALARMS) UNIT (Unit alarms)
The screen will indicate if there are any Unit Faults. If not, it will display ‘NONE’. Pressing
ENTER takes the user back to the previous menu.
UNIT FAULT: -12 VOLT PSU
IS UNDER-VOLTAGE
6.2.6.1.2
(MONIT: ALARMS) RECEIVE (Receive alarms)
The screen will indicate if there are any Receive Traffic Faults. If not, it will display ‘NONE’.
Pressing ENTER takes the user back to the previous menu.
RX TRAFFIC: AGC ALARM
REDUCE COMPOSITE I/P LVL
6–30