5 bulk commands – Comtech EF Data CDM-550T User Manual
Page 139
CDM-550T Satellite Modem
Revision 3
Remote Control
MN/CDM550T.IOM
15.6.5
Bulk Commands
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(note that all arguments are ASCII numeric codes, that is,
ASCII codes between 48 and 57)
Response to Command
(target to controller)
Query
(Instruction
Code and
qualifier)
Response to
query
(target to
controller)
Global
Configuration
MGC= 78
bytes,
with
numerical
entries, fixed
value entries,
and delimiters
Command or Query.
Global configuration of unit, in the form:
FFF.FFFFDDDD.DDDGRMVSPP.PCXfff.ffffdddd.dddgrmvswwct
t.tbIOTZAAAAAUEEEEBYYY.YYW, where:
FFF.FFFF = Tx Frequency - same as TFQ= (8 bytes)
DDDD.DDD = Tx Data Rate - same as TDR= (8 bytes)
G = Tx FEC Coding type - same as TFT= (1 byte)
R = Tx FEC Code Rate - same as TCR= (1 byte)
M = Tx Modulation - same as TMD= (1 byte)
V = Tx Spectrum Invert - same as TSI= (1 byte)
S = Tx Scrambler State - same as TSC= (1 byte)
PPPP = Tx Power Level - same as TPL= (4 bytes)
C = Tx Clock Source - same as TCK= (1 byte)
X = Tx Carrier Status - same as TXO= (1 byte)
fff.ffff = Rx Frequency - same as RFQ= (8 bytes)
dddd.ddd = Rx Data Rate - same as RDR= (8 bytes)
g = Rx FEC Decoding type - same as RFT= (1 byte)
r = Rx FEC Code Rate - same as RCR= (1 byte)
m = Rx Modulation - same as RMD= (1 byte)
v = Rx Spectrum Invert - same as RSI= (1 byte)
s = Rx De-scrambler - same as RDS= (1 byte)
ww= Rx Sweep Width - same as RSW= (2 bytes)
c = Rx Clock Mode - same as RCK= (1 byte)
tttt = Eb/No Alarm Point - same as EBA= (4 bytes)
b = Rx Buffer Size - same as RBS= (1 byte)
I = Unit Interface Type - same as ITF= (1 byte)
O =Unit Framing Mode - same as FRM= (1 byte)
T = Unit Test Mode - same as TST= (1 byte)
Z = Unit IF Impedance - same as IMP= (1 byte)
AAAAA = Alarm Mask - same as MSK= (5 bytes)
U= ODU Comms - same as ODU= (1 byte)
EEEE= EDMAC Slave address - same as ESA= (4 bytes)
B= AUPC enable - same as AUP= (1 byte)
YYYYYY = AUPC setup - same as APP= (6 bytes)
W =Stats log interval- same as SSI (1 byte)
Example:
MGC=074.56780064.0001720112.720082.65430
128.0002320116109.81211100000102361115.659
MGC= (message ok)
MGC? (received ok,
but invalid arguments
found)
MGC? MGC=FFF.FFFF
DDD.DDDRMVS
PP.PCXfff.ffffddd
.dddrmvswwctt.t
bIOTZAAAAAUE
EEEBYY
Y.YYW
(same format as
command
arguments)
15–23