6 end of packet, 6 remote commands and queries – Comtech EF Data CDM-550T User Manual
Page 121
CDM-550T Satellite Modem
Revision 3
Remote Control
MN/CDM550T.IOM
15.5.6
End Of Packet
Controller to Target: This is the 'Carriage Return' character (ASCII code 13).
Target to Controller: This is the two-character sequence 'Carriage Return', 'Line Feed'. (ASCII
code 13, and code 10). Both indicate the valid termination of a packet.
15.6 Remote Commands and Queries
The following remote commands are arranged in the following order:
¾ 15.6.1 Transmit (Tx) Commands and Queries
¾ 15.6.2 Receive (Rx) Commands and Queries
¾ 15.6.3 Unit Remote Commands and Queries
¾ 15.6.4 Remote Queries
¾ 15.6.5 Bulk Commands
TX Priority System = TIT (Highest priority) , TFM, TFT, TMD, TCR, and TDR (Lowest
Priority), indicated by shading. Any change to a higher priority parameter can override any of the
parameters of lower priority.
RX Priority System = RIT (Highest priority) , RFM, RFT, RMD, RCR, and RDR (Lowest
Priority), indicated by shading. Any change to a higher priority parameter can override any of the
parameters of lower priority.
Exception: Select INSERT mode using RFM (Receive Framing type) which is highest priority.
Note: The following codes are used in the ‘Response to Command’ column:
=
Message ok
?
Received ok, but invalid arguments found
*
Message ok, but not permitted in current mode
15–5