Eb/No Alarm
Point
EBA= 4
bytes,
numerical
Command or Query.
Eb/No alarm point, with a range of Eb/No between 0 and 16 dB.
Resolution 0.1 dB.
Example: EBA=12.3 (which is Eb/No = 12.3 dB)
EBA= (message ok)
EBA? (received ok,
but invalid arguments
found)
EBA? EBA=xx.x
(same format
as command
arguments)
Rx Buffer Size
RBS=
1 byte, value of
1,2,3,4 or 5
Command or Query.
Rx buffer size, where:
1 =
± 256 bits
2 =
± 512 bits
3 =
± 1024 bits
4 =
± 2048 bits
5 =
± 4096 bits
RBS= (message ok)
RBS? (received ok,
but invalid argument
found)
RBS* (message ok, but
not permitted in current
mode)
RBS? RBS=x