beautypg.com

Comtech EF Data CRS-150 User Manual

Page 22

background image

CRS-150 1:1 Redundancy Switch

Revision 2

Introduction

MN/CRS150.IOM

1–6

IF Switching/

Splitting

Transmit IF: Switched by RF relay (0.3 dB max loss)

Receive IF: Passive power splitting (3.5 dB max loss)

IF Impedance

• Optimized for 50Ω (> 20 dB return loss on external IF ports)

• 75Ω supported with the use of external RF transformers (supplied)

IF Connectors

BNC female

IF Frequency range

52-176 MHz

Weight

4.6 lbs (2.1 kg)

Dimensions

1.75 inches (44.5 mm) high, 19 inches (482.5 mm) wide, 4.2 inches (107 mm) deep

(excluding connectors)

Power requirements

4.5 Watts maximum

+ 12 volts DC @ 250 mA (max)

-12 volts DC @ 120 mA (max)

• Power is supplied by the Online and Standby Modems, and the unit current shares

when both an >A= and >B= unit are present. These power supplies are electronically
fused and protected.

• A pair of auxiliary DC inputs are provided for powering external equipment connected to

the main data interface, such as a CIC-20 Interface Converter.

Approvals

• ‘CE’ as follows:

o

EN 55022 Class B (Emissions)

o

EN 50082-1 (Immunity)

o

EN 60950 (Safety)

• FCC Part 15 Class B