9 remote (j20), 10 ethernet (j21) (future option) – Comtech EF Data DMDVR20 LBST Rev 1.1 User Manual
Page 74
DMDVR20 LBST Satellite Modem
Rear Panel Interfaces
TM136 – Rev. 1.1
5-5
5.3.9 REMOTE (J20)
The Remote Port is a RS-485 or RS-232 Connection for remote monitor and control of the
modem. It is a 9-Pin Female “D” Connector. Refer to Table 5-4 for pinouts.
Table 5-4. Remote Port (RS-485 or RS-232) 9-Pin Female “D” Connector (J20)
Pin No.
Signal Name
Signal
Direction
1
Transmit Data RS-485 (+)
TX-485-B
Output
2
Transmit Data RS-232
TXD-232
Output
3
Receive Data RS-232
RXD-232
Input
4 NC
NC
---
5 Ground
GND
---
6
Transmit Data RS-485 (–)
TX-485-A
Output
7 NC
No
Connection
---
8
Receive Data RS-485 (+)
RX-485-B/CTS
Input
9
Receive Data RS-485 (–)
RX-485-A
Input
When operating the remote port as RS232 using a cable pinned 1 for 1
may cause communication failures due to miss routing of standard
RS232 com port signals.
When operating the remote port as RS232, the cable used should only
have pins 2, 3 and 5 connected.
5.3.10 ETHERNET (J21) (FUTURE OPTION)
The ETHERNET Port (J21) can be used for the Monitor & Control (M&C) Functions of the unit.
The physical interface is a standard female RJ-45 Connector.