Rear Panel Interfaces

DMDVR20 LBST Satellite Modem

5-2

TM136 – Rev. 1.1

5.2 Power Input Modules

5.2.1 AC Power Input Module


AC Input Module (Figure 5-1) is located on the left side of the unit. Power applied to the port with
the supplied power cable is 100 – 240 VAC, 50 – 60 Hz. Integrated into the Power Input Module
is the Power On/Off Rocker Switch. Power consumption for the unit is 1A. A chassis ground
connection (#10-32 threaded stud), is located to the lower right of the module .5.2.2 DC Power
Input/Switch

The Optional DC Power Input and Switch (Figure 5-1) is available for all DMDVR20 LBST
products. The unit may be powered from a 36 – 75 VDC source with a maximum unit power
consumption of 3 A. Refer to Table 5-1 for pinouts.

Table 5-1. DC Power

A –

B Ground

C +

5.3 DMDVR20 LBST Chassis Connections

5.3.1 EXT REF (J10)


The External Reference Port is a 50-Ohm Female BNC Connector and will accept the following
frequencies: 1.0, 1.544, 2.0, 2.048, 5.0, and 10.0 MHz.

5.3.2 TX L-Band IF (J11)


The Transmit Output Port is a 50-Ohm Type-N Connector. The power level is programmable
from 0 to -25 dBm, in 0.1 dBm steps. The IF Frequency can be programmed to 950 – 2050 MHz,
in 1 Hz Steps.

5.3.3 RX (J1)


The Receive Input Port is a 75-Ohm F-Type Connector. The IF Frequency can be programmed
from 950 to 2150 MHz in 1 Hz Steps.

5.3.4 ALARM (J15)


The Alarm Port is a 15-Pin Female “D” Connector. Refer to Table 5-2 for pinouts.

Table 5-2. ALARM Port 15-Pin Female “D” Connector (J15)

Pin No.

Signal Name

Signal

Direction

1

Mod Fault

MF-C

No Direction

2

Mod Fault

MF-NC

No Direction

3

Mod Fault

MF-NO

No Direction

4

Demod Fault

DF-C

No Direction

5

Demod Fault

DF-NC

No Direction