IP1500 and IP2500 Series
Administrator Guide
Special Warning: High Voltage – Range 37 - 57V DC <12.96 watts (27mA)
Grounding
The IP2500 series is UL 2017 safety rated. Due to the standard PoE 802.3af power supplied by the
remote (IEEE 802.3af or “at” rated) PoE Switch, the IP2500 has a protective earthing terminal cable
available. There must be an uninterruptible safety earth ground attached to the grounding lanyard
provided. Whenever it is likely that the protection has been impaired, disconnect the Ethernet cable
until the ground has been restored. This is a non-emergency, non-monitored product line.
Ground terminations points have been marked in accordance with UL 2017 standards. Approved
icons have been applied to indication the grounding location.
Ground Wire Connection
Locate the 18g green ground wire, which is terminated with a ring lug that has been secured to a
faceplate stud. The loose end of the green ground wire must be secured to an earth ground nearby.
If the enclosure has marked grounding location, and a green grounding screw is available, please
use it whenever local codes dictate earth ground is required. Ground termination locations can be
labelled using the following graphic symbol:
Ground Images sample:
There are no user-serviceable parts inside these products. Any servicing, adjustment, maintenance
or repair must be performed only by service-trained personnel. These products do not have a power
switch; they are powered on when the Ethernet PoE cable is plugged in.
ELECTRICAL SAFETY WARNINGS
This device is suitable for use in non-hazardous locations only.
WARNING: Explosion Hazard – Do not replace the device unless power has been switched off or
the area is known to be non-hazardous.
WARNING: Do not operate the equipment in the presence of flammable gasses or fumes. Operating
electrical equipment in such an environment constitutes a definite safety hazard.
WARNING: If the equipment is used in a manner not specified by Code Blue Corp., the protection
provided by the equipment may be impaired.
WARNING: Do not perform any services on the unit unless qualified to do so. Do not substitute
unauthorized parts or make unauthorized modifications to the unit.
WARNING: Properly ground the unit before connecting anything else. Units not properly grounded
may result in a safety risk and could be hazardous and may void the warranty. See the
grounding technique section for proper ways to ground the unit.
WARNING: Do not operate the equipment in a manner not specified by this manual.
WARNING: Do not work on equipment or cables during periods of lightning activity.
WARNING: Install only in accordance with Local & National Codes of Authorities Having
Jurisdiction.
(Revised 2010-11-15) 5