beautypg.com

Cb 1 series, Administrator guide – Code Blue CB 1-E ECONOMICAL HELP POINT User Manual

Page 51

background image

Code Blue

259 Hedcor Street

Holland, MI 49423 USA

800.205.7186

www.codeblue.com

GU-157-E

page 51 of 71

CB 1 Series

Administrator Guide

1. Remove the clear dome top lens
2. Remove strobe light Casting and set aside
3. Remove reflector plate
4. Reach down, alongside the area light and

unplug the three prong plug

5. Uncouple and discard old area light

PARTS LIST

• (1) #11804, A-700 LED Area Light

• (1) #11950, Red/Black Wire Harness

• (1) #11878, Plug-in Transformer

6. Set the new LED area light in the position and

plug the transformer in (the transformer can

be located in the LED area light channel or

below on the power strip)

7. Set the new reflector plate in place
8. Replace the dome top and secure
9. Replace the dome top lens and secure
10. Test unit



Ž



Œ

1. S-100 120V AC, obsolete

(#10151)

2. HPS Area Light

(#40024) or

Metal Halide 120V AC

(#40070)

3. 7-watt Fluorescent

Phone Faceplate

Light, obsolete

4. 6 Plug-in Slot Power

Strip, obsolete

Fig. 2

Fig. 3

CONVERTING 120 VOLT PLUG-IN STRIP TO A-700 LED