20 Line Power Installation Instructions
(Excludes NightCharge
®
and Solar Options)
IMPORTANT: All wiring shall comply with national and local codes governing this installation. It is
the responsibility of the installer to ensure these conditions are complied with.
1.0 SUPPLY WIRING
1.1 Pulling the power wires – Wire should be a minimum of 14 AWG and be pulled into the unit,
leaving a minimum of two feet of wire from the opening of the conduit.
1.2 Pulling the communications wire (if needed) – Communications wire must be shielded phone
line. The phone line must be pulled into the unit using a separate conduit from the power,
and be run so as to extend a minimum of two feet out of the phone opening.
2.0 CONNECT THE POWER WIRES
2.1 Make the connections – Locate the grounding lug and connect the ground wire.
2.2 Using 115V AC supply – Connect the colored (hot) wire to the black wire, and connect the
white or gray (neutral) wire to the white wire.
2.3 Higher voltage supply – If the unit was ordered for a higher voltage, a pre-wired power brick
will be located on the top of the electrical panel with a 24 volt secondary to supply the low
voltage manifold and power brick to supply the area light. Connect the colored (hot) wire and
the white or gray (neutral) wire to the white wire in the junction box.
3.0 CONNECT THE PHONE LINE (if required) – See phone Installation Instructions.
4.0 APPLY POWER – The unit should become operational immediately after the power is ener-
gized.