beautypg.com

Cb 1 series, Administrator guide – Code Blue CB 1-E ECONOMICAL HELP POINT User Manual

Page 41

background image

Code Blue

259 Hedcor Street

Holland, MI 49423 USA

800.205.7186

www.codeblue.com

GU-157-E

page 41 of 71

CB 1 Series

Administrator Guide

4.5

Attach the phone wires from the GSM assembly to terminals 1 and 2 on the IA4100

4 pin connector.

4.6

Set up GSM card. Refer to GSM digital set up instructions.

5.0 CONNECT THE POWER WIRES

5.1

Make the connections – First, locate the grounding lug and connect the ground wire,

leaving a minimum of six inches of slack. Second, using #8 forks, connect the power

wires.

5.2

Using 115V AC supply: Connect the colored (hot) wire to the terminal screw furthest

to the left (#1) on the terminal strip. Connect the white (neutral) wire to the terminal

screw second to the left (#2) on the terminal strip.

5.3

Higher voltage supply: If the unit was ordered for a higher voltage, a multi-tap trans-

former will be located at the top of the electrical panel. Be sure to connect your power

wires to the correct terminal screws on the top of the transformer as labeled. Complete

the connection by attaching the terminal cover that is supplied.

IMPORTANT: If the power is applied to the incorrect terminal screws, damage will occur to

the unit. This damage will NOT be covered by any Code Blue warranty.

6.0 INSTALL THE BATTERY

IMPORTANT: Batteries MUST be fully bench charged before installation.

6.1

Place the battery into the unit – The battery should be placed in the bottom of the unit

(in a CB 1 or CB 9 unit the battery shelf will need to be set in place first).

6.2

Connect the wires – First connect the blue wire to the positive lug on the battery, then

connect the black wire to the negative lug.

7.0 APPLY POWER

7.1

Once power is applied, the unit will start the charging process.