beautypg.com

Cb 1 series – Code Blue CB 1-E ECONOMICAL HELP POINT User Manual

Page 40

background image

Code Blue

259 Hedcor Street

Holland, MI 49423 USA

800.205.7186

www.codeblue.com

GU-157-E

page 40 of 71

CB 1 Series

Administrator Guide

22 NIghtCharge® Installation Instructions

CAUTION: Do NOT apply power to the unit until all other conditions are made. See

Step 6.

IMPORTANT: All wiring shall comply with national and local codes governing this installation.

It is the responsibility of the installer to ensure these conditions are complied with.

1.0 SUPPLY WIRING

1.1

Pulling the power wires – Wire should be a minimum of 14 AWG and be pulled into

the unit, leaving a minimum of two feet of wire from the opening of the conduit.

1.2

Pulling the communications wire (if needed) – Communications wire must be shielded

phone line. The phone line must be pulled into the unit using a separate conduit from

the power, and run to extend a minimum of two feet out of the phone opening.

2.0 CONNECT THE PHONE LINE (if needed) – See phone installation instructions.

3.0 OPTIONAL DIGITAL TRANSCEIVER (Model CB 1)

3.1

Remove GSM digital panel assembly from carton and hang over mounting plate inside

unit behind phone opening.

3.2

The antenna is installed inside the dome top assembly at the factory.

NOTE: Dome top assembly may need to be rotated so antenna is positioned to achieve

best signal.

3.3

Attach antenna cable male TNC fitting to the GSM enclosure female TNC fitting.

3.4

Attach the GSM positive Red wire to terminal strip screw #8 location and the negative

Black wire to terminal strip location #5.

3.5

Attach the phone wires from the GSM assembly to terminals 1 and 2 on the IA4100

4 pin connector.

3.6

Set up GSM card. Refer to GSM digital set up instructions.

4.0 OPTIONAL DIGITAL TRANSCEIVER

4.1

Remove GSM digital housing assembly from carton and mount assembly to the pole

using banding provided.

4.2

The antenna is installed to the 2-gang bell box at the factory. Mount the antenna as-

sembly to the pole using the banding provided. Assembly may need to be rotated to

achieve best signal.

4.3

Attach antenna cable male TNC fitting to the GSM enclosure female TNC fitting.

4.4

Attach the GSM positive red wire to terminal strip screw #8 location and the negative

black wire to terminal strip location #5.