Powering the Live1

ON

PS 1

10063 PSU

THIS UNIT MUST BE

CONNECTED TO PROTECTIVE

EARTH

No user serviceable

parts

Refer all maintenance

to a qualified

engineer

ENERGY

HAZARD

AC POWER

INPUT

100V to 240V

50/60Hz

FUSE: T5A (100V)

T3.15A (240V)

+15V at 5A
-15V at 5A
+12V at 4A

Serial No.

DC

POWER

OUTPUT

FOR USE WITH

CADAC LIVE1

SERIES ONLY

The Live1 is powered from an external, rackmountable (2U) Power Supply Unit
(PSU). The AC mains switch is located on the front panel of the PSU, and the
mains is connected via an IEC receptacle on the rear panel. An IEC cable is
supplied with the PSU to connect this to the mains supply. The cable should be
fi tted with a mains plug suitable for your country, if this is not the case, either
obtain one of the appropriate type, or replace the fi tted plug with one of the
correct type. Note the mains cable colour coding is as follows:

Mains connection

Mains cable core colour

Live

Brown

Neutral

Blue

Earth (Ground)

Green/Yellow

The PSU in the Live1 is a “Universal” type, and may be connected to any AC
mains supply voltage of between 100 and 240 V, and frequency 50 or 60 Hz.

The IEC receptacle has an integral mains fuseholder (below the connector). If it
is necessary to replace this fuse, please only do so with one of the same type
and rating:

115 V AC

230 V AC

Fuse type

20 mm dia. anti-surge

Fuse Rating

T5A (5 A)

T3.15A (3.15 A)

This fuse is the only user-replaceable component the Live1 contains. A mains
fuse should never be replaced without fi rst making an attempt to ascertain the
reason for its failure. If you are unsure why the fuse failed, or if the replacement
fuse also fails immediately, consult your Cadac dealer.