Powering the live1, Ps 1 – Cadac LIVE1 User Manual
Page 11

Revision L1.1 2011-12
Live1
11
Powering the Live1
ON
PS 1
10063 PSU
THIS UNIT MUST BE
CONNECTED TO PROTECTIVE
EARTH
No user serviceable
parts
Refer all maintenance
to a qualified
engineer
ENERGY
HAZARD
AC POWER
INPUT
100V to 240V
50/60Hz
FUSE: T5A (100V)
T3.15A (240V)
+15V at 5A
-15V at 5A
+12V at 4A
Serial No.
DC
POWER
OUTPUT
FOR USE WITH
CADAC LIVE1
SERIES ONLY
The Live1 is powered from an external, rackmountable (2U) Power Supply Unit
(PSU). The AC mains switch is located on the front panel of the PSU, and the
mains is connected via an IEC receptacle on the rear panel. An IEC cable is
supplied with the PSU to connect this to the mains supply. The cable should be
fi tted with a mains plug suitable for your country, if this is not the case, either
obtain one of the appropriate type, or replace the fi tted plug with one of the
correct type. Note the mains cable colour coding is as follows:
Mains connection
Mains cable core colour
Live
Brown
Neutral
Blue
Earth (Ground)
Green/Yellow
The PSU in the Live1 is a “Universal” type, and may be connected to any AC
mains supply voltage of between 100 and 240 V, and frequency 50 or 60 Hz.
The IEC receptacle has an integral mains fuseholder (below the connector). If it
is necessary to replace this fuse, please only do so with one of the same type
and rating:
115 V AC
230 V AC
Fuse type
20 mm dia. anti-surge
Fuse Rating
T5A (5 A)
T3.15A (3.15 A)
This fuse is the only user-replaceable component the Live1 contains. A mains
fuse should never be replaced without fi rst making an attempt to ascertain the
reason for its failure. If you are unsure why the fuse failed, or if the replacement
fuse also fails immediately, consult your Cadac dealer.