Factory settings for global parameters
M 01 global parameters 1911-4 / 1912-4:
Pos.
Global parameters 1911-4 / 1912-4
Value
Unit
01
CLAMP FWD. TO PART
0.8
sec
02
TILL CLAMP DOWN
0.3
sec
03
TILL VACUUM OFF
0.3
sec
04
THREAD LENGTH, BOBBIN FULL
004
m
05
TILL CLAMP INSERTING
0.2
sec
06
SEWING END ->CL.SIDEW
0.1
sec
07
TIME AFTER CLAMP OPEN
0.5
sec
17
TILL TENSION OPEN
0.00
sec
18
DURATION OF TENS. OPEN
0.2
sec
19
TILL THREAD CLAMP FORW.
0.5
sec
20
DUR.THREAD CLAMP FORW.
0.6
sec
29
TILL SWING RETAINER DWN.
0.0
sec
30
TILL RETAINER SWINGS
0.0
sec
31
DUR.OF PULLING RETAINER
0.0
sec
32
BLOW OUT THE PART
0.5
sec
33
CLAMP MOVES TO STACKER
0.0
sec
35
THREAD CATCH. "UP" POS
023
INC
36
SWITCH ON POS.OF TRIMM.
100
INC
37
TRIMMING SPEED
180
Upm
38
DURATION OF TRIMMING
0.35
sec
39
THREAD CATCH.TURNS BACK
25
INC
40
PROCESS IN STEPS
00