Programming – Beisler 1911-4 User Manual
Page 79

- D 79 -
Short Seam Automat 1911-4 / 1912-4 Working Instructions
Beisler Automated Sewing Equipment
D.3
Programming
D.3.5 List of special parameters
Special parameters are values that refer to only one
specific sewing program. Changes of these values affect
only the currently selected sewing program for which the
setting is made.
Special parameters are edited in four different levels (level
2 to level 5).
Special parameters can be functions that may be enab-
led or disabled or parameter values that are set in lists.
&'(6
)@7
Request / exit special parameter menu:
Select sewing program and change from start level to
level 1:
•
Press
key.
Request special parameter menu:
•
Press
( key and request submenu.
Exit menu:
•
Press
key.
No.
Programmable special parameters in list (F3)
01
CLAMP POSITION RIGHT:
Clamp position right during piece transfer (must be programmed for 1912)
02
TILL GUIDE TO WORK POS.
Distance to move to stop point
03
INSERT SPEED .........:
Clamp insertion speed
04
CLAMP SPEED ..........:
Clamp transport speed
05
DISTANCE TILL SEWING
Distance moved till sewing starts
06
SEWING SPEED 1 .......:
Sewing speed 1 (beginning of seam)
07
SEWING SPEED 2 .......:
Sewing speed 2 (main seam)
08
SEWING SPEED 3 .......:
Sewing speed 3 (end of seam)
09
DISTANCE SEWING SPEED 1
Distance for slow sewing (sewing speed 1)
10
DISTANCE SEWING SPEED 3
Distance for slow sewing at end of seam (sewing speed 3)
12
THREAD MONITOR ON AFTER
Top thread monitor on (distance in mm after beginning of sewing process)
13
TOP THREAD MON. FILTER:
Filter for top thread monitor (response delay)
14
BOTTOM THREAD MON. FILTER
Filter for bottom thread monitor (response delay)
16
TACKING LENGTH SEAM BEG.
Initial bar tack length (only lock stitch)
17
TACKING LENGTH SEAM END
Final bar tack length (only lock stitch)