5 Installation
BECKHOFF
Drive Technology
42
Version : 4.6
AX5000
5.3
Motors and cables
With longer motor cables the resulting commutation currents can affect the control quality
and lead to EMC faults. Use the tables below to check whether motor chokes or mains filters
have to be used in your application. When selecting the control cabinet ensure that there is
adequate space for motor chokes, mains filters, etc.
Lay the power and signal cables in separate metal cable ducts or, if both types of cable use
the same metal cable duct, make sure there is an earthed metal dividing wall between the
cables.
Maximum cable length (including extensions) for a rated motor voltage up to 400 V
Motor choke
AX5101 - AX5112 a.AX52xx
AX5118 a. AX5125
AX5140
C2
1)
C3
C2
2)
C3
C2
C3
Without
< 25 m
< 25 m
< 25 m
< 25 m
-
< 35 m
AX2090-
MD50-0012
< 100 m
< 100 m
-
-
-
-
AX2090-
MD50-0025
-
-
< 50 m
< 50 m
-
-
1)
For compliance with EN 61800-3 only with mains filter AX2090-NF50-0014.
2)
For compliance with EN 61800-3 only with mains filter AX2090-NF50-0032.
In exceptional cases (sensitive sensors, etc.) it can be necessary to use a motor choke even
for motor cable lengths < 25 m.
Maximum cable length (including extensions) for a rated motor voltage up to 480 V
Motor choke
AX5101 - AX5112 a.AX52xx
AX5118 a. AX5125
AX5140
C2
1)
C3
C2
2)
C3
C2
C3
Without
< 20 m
< 20 m
< 20 m
< 20 m
-
< 35 m
AX2090-
MD50-0012
< 100 m
< 100 m
-
-
-
-
AX2090-
MD50-0025
-
-
< 50 m
< 50 m
-
-
1)
For compliance with EN 61800-3 only with mains filter AX2090-NF50-0014.
2)
For compliance with EN 61800-3 only with mains filter AX2090-NF50-0032.
In exceptional cases (sensitive sensors, etc.) it can be necessary to use a motor choke even
for motor cable lengths < 20 m.
Note
We recommend that feedback wires and motor wires used have the same
length.