5 installation, 1 mechanical installation, 1 installation in the control cabinet – BECKHOFF AX5000 1,5 A - 40 A User Manual
Page 30: 5installation

5 Installation
BECKHOFF
Drive Technology
30
Version : 4.6
AX5000
5
Installation
WARNING
Caution – Risk of injury!
•
The servo drives may only be installed by trained, qualified personnel.
The qualified personnel must know and comply with the national accident
prevention regulations.
•
Safety boots must be worn.
WARNING
Caution - Risk of injury through electric shock!
De-energise all electrical components (servo drive, control cabinet, etc.)
before commencing the installation or deinstallation.
5.1
Mechanical installation
Attention
Destruction of the servo drive!
•
Always install the servo drive vertically.
•
Provide adequate ventilation for the servo drive. The permissible ambient
conditions are specified in the "Technical data" section.
•
It is essential to adhere to the required distances (see diagrams below).
5.1.1
Installation in the control
cabinet
WARNING
Caution - Risk of injury through electric shock!
The mounting plate must be earthed according to the statutory regulations.
Attention
Grounding!
If the ground connection of the AX5000 is not done as specified it is
possible to get trouble with some EMC issues.