7 overview of connectors/terminal points, 1 x01 - wide voltage input, 2 x02 - dc link (ax5101 - ax5125 und ax520x) – BECKHOFF AX5000 1,5 A - 40 A User Manual
Page 23: 3 x02 - dc link (only ax5140), 4 x03 - 24 vdc supply

BECKHOFF
Drive Technology
4 Product description
AX5000
Version : 4.6
23
4.7
Overview of connectors/terminal points
4.7.1
X01 - wide voltage input
Terminal point
Connection
Tightening
torque
3-phase
1-phase
L1
Phase L1
Phase L1
0,5 -0,6 Nm
L2
Phase L2
not used
L3/ N
Phase L3
Neutral conductor
PE
Protective conductor
4.7.2
X02 - DC link (AX5101 - AX5125 und AX520x)
Terminal point
Connection
Tightening
torque
DC+
DC link +
external brake resistor
and drive system
0,5 -0,6 Nm
DC –
DC link –
4.7.3
X02 - DC link (Only AX5140)
Terminal point
Connection
Tightening
torque
DC+
DC link +
only for drive system
1,2 -1,5 Nm
DC –
DC link –
WARNING
Serious risk of injury through high electrical voltage!
890 V DC voltage at the DC link terminals. Dangerous voltage may be
present for 5 minutes after the device is switched off.
Remove the connector only if you want to build a drive system with a AX-
Bridge.
Remove the white hexagon plugs only if you wire the terminal points again.
4.7.4
X03 - 24 V
DC
supply
Terminal
point
Connection
Current
consumption
Tightening
torque
U
p
+
24 V
DC -0/+25%
- periphery
(e.g. separate braking
voltage)
Depending on the
connected consumers
(see X06 and X14,X24)
0,5 – 0,6 Nm
U
s
+
24 V
DC ±25%
- system
supply (depending on
rated current)
-12 A = 0.4 A – 0.8 A
18 A - 25A = 1,1 A
40 A = 1,6 A
GND
GND