2 electrical installation – BECKHOFF AX5000 1,5 A - 40 A User Manual
Page 32

5 Installation
BECKHOFF
Drive Technology
32
Version : 4.6
AX5000
5.2
Electrical installation
UL-Listing!
It is essential to observe chapter 3.3 if you wish to operate an AX5000 in
USA or Canada.
DANGER
Serious risk of injury through electric shock!
Due to the DC link capacitors dangerous voltage may persist at the DC link
contacts "X02" after the servo drive has been disconnected from the mains
supply. After disconnecting the servo drive wait 5 minutes and measure the
voltage at the DC link contacts DC+ and DC-. The device is safe once the
voltage has fallen below 50 V.
WARNING
Caution – Risk of injury through electric shock!
•
Before installation, wiring and commissioning it is essential to read the
section on "Safety".
•
Before installing, uninstalling or connecting the servo drive and the
motors please note the following:
- Remove all relevant mains fuses.
- Switch off the main system switch and secure it with a lock.
- Put up a warning sign.
•
The control and power connections for the motors may be live, even if
the motor is prevented from rotating by the internal brake.
Attention
Destruction of the equipment!
•
Check the rated voltage and current of the servo drive and the connected
motors.
•
When the AX5000 is disconnected from the mains supply (emergency
stop, mains contactor etc.), wait at least 3 minutes before starting again
or query the status of the IDN "P-0-0205" (see documentation of the
“IDN-Description”).