ZC Kit – AGP Pellet Insert

(94400157)

Page 2 of 10

17601823 - 3/7/14

© Travis Industries, Inc.

Vent Requirements

 Must be 3” or 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a

factory built type "A" chimney. All vent joints (including adapters, elbows, etc…) must be sealed with 500°
F. RTV silicone.

 Pellet vent must maintain a minimum 3" clearance to any combustible (install vent at clearances specified

by the vent manufacturer).

 Do not connect the pellet vent to a vent serving any other appliance or stove.
 The maximum venting distance is

shown in the illustration to the right.

 Do not install a flue damper in the

exhaust venting system of this unit.

 Use an approved wall thimble when

passing the vent through walls and a
ceiling support/fire stop spacer when
passing the vent through ceilings
(make sure to maintain 3" clearance to
any combustibles.

 No more than 180° of elbows (two 90°

elbows, one 90° and two 45° elbows,
etc.).

 Pellet vent connections must be

sealed airtight with 500° F. RTV
silicone and screwed together with at
least three sheet metal screws (unless
the vent manufacturer’s requirements
specify otherwise).

Vent must have a support bracket
every 5' of pellet vent when exterior of
structure

 Horizontal sections must have a 1/4"

rise every 12" of travel.

0 Feet

5 Feet

10 Feet (max.)

0 Feet

5 Feet

10 Feet

15 Feet

20 Feet

25 Feet

The vent height and run
must not exceed the

distance shown in the

shaded region shown to the

right.

NOTE: To achieve optimum

performance, we

recommend keeping the
vent as short as possible

(horizontal run especially).

Venting into this shaded

area may require restrictor

adjustment to the closed
position. See the section

"Restrictor Adjustment" in

the manual for details.

30 Feet

35 Feet

40 Feet

(max.)