19. The completed log set is shown below.

20. Set the exhaust restrictor to the required position as shown in the table below. The insert should be test-burned with the

glass frame in place prior to leaving the installation. See the owner’s manual for details on finalizing the installation
(adjusting the air shutter, etc.).

Restrictor Settings

Traditional Logs

Natural Gas Short Vent (25’ or less)

#3

Natural Gas Tall Vent (25’ or more)

#4

Propane Short Vent (25’ or less)

#2

Propane Tall Vent (25’ or more)

#4